This is our state of the art DATA CENTER

Location
The data center is located in a subterranean (i.e. underground) Class A building.

Fire Protection
All data center areas, including facilities support areas, are protected by halon 1301 in addition to water sprinkler systems. Different types and models of Fenwall brand smoke and fire protection electronics are used. The system is inspected daily by facilities personnel and is maintained semi-annually by the original installation contractor.

Backup Generator
The emergency power generation gear consists of 3 Caterpillar, 750 kw (continuous duty), generator/engine sets and General Electric switchboards and breakers. This gear is also configured to perform peak shaving (co-generation) as well as emergency service. The generator plan serves all critical computer loads and associated support hardware. Facilities personnel perform daily inspections and weekly load tests to ensure reliability. Two factory authorized service centers are used to provide emergency and annual maintenance.

Power Feeder
The data center utility power main service feeder is 4,000 amps, at 480 volts and enters the building in a General Electric AV-Line switchboard.

Power Supply
Computer grade power is supplied through 2 separate, Emerson Electric, UPS systems. The 415Hz system consists of 3 paralleled 169 kw modules (model AP96) and are 480 volts in and 208 volts out. The 6OHz system is 3 paralleled 450 kw modules (model AP56) and are 480 volts in and out. Both systems share 3 paralleled strings of C&D (model LCWC-25) batteries. Computer grade power is distributed through Liebert (model PPA-225) 225 kva power distribution units.

Chillers
The data center water chilling plant consists of 3 Trane Centravac, 400 ton, centrifugal chillers (with Barber Coleman controls) and 3 Baltimore Aircoll cooling towers (model 2422-C). Several models of Liebert air handling units are used to cool the data center and support areas.

Backups
We use the StorageTek Timberwolf 9714 DLT 7000 library and Legato Enterprise backup software. All systems are fully backed up every Sunday and incrementally each day thereafter. Tapes are stored off-site in a fire proof safe.

Raised Flooring
The data center contains approximately 22,500 usable square feet of raised computer flooring.

Environment Control
Computer room environmental controls are provided by industry standard Liebert Air Handling units and Trane Centrifugal water chillers. Existing chilled water connections are available, under the raised computer room floor, for support of water cooled mainframe processors. All mechanical support systems are inspected daily by facilities personnel and maintained monthly, annually, and as
needed by factory authorized vendors.

UPS and PDU
Computer grade power is supplied by industry standard Emerson Electric Uninterruptible Power Supply (UPS) systems and Liebert Power Distribution Units (PDU). All UPS and PDU hardware is inspected daily by facilities personnel and maintained quarterly, annually, and as needed by Liebert factory engineers.

Access
Physical security (access control and alarm handling) is controlled by a newly installed Casi-Rusco system with Indala proximity card readers. Current security services consist of in-house contract security guard coverage 24 hours a day, 365 days a year. Numerous security cameras are deployed throughout the facility and are connected to video recording equipment and monitors.

NOC
Our Network Operations Center (NOC) is staffed 24 x 7 and are continuously monitoring all aspects of our servers and network.

Personnel
Our staff includes highly trained and certified engineers that have dedicated their career to Internet web hosting.

Co-location
We provide continuos monitoring of our co-location room. We can provide QOS dedicated 10/100 Megabytes of fast Ethernet switched access to the Internet.

Connections
Redundant OC12 and T3 connections.  Redundant  Backbone Services are Provided by UUNET, Sprint and Savvis . We are currently upgrading to Redundant OC3 (155Mb) to each provider. Our internal network is 10/100 Mb/s switched fast Ethernet. We are using Cisco 7513 routers and Catalyst 5500 switches.

Sign-up

Please read A1 Hosting Acceptable Use Policy

Dedicated Servers

Faq Index

 About Us
 Cgi Scripts
 Domain Names
 Ecommerce
 Email
 Internet Basics
 Promoting
 Statistics
 Web Management

Subscribe to  the  Free "Search Engine  hot News" news letter and receive the  the FREE step by step marketing guide  (a $19.95 value)
your name

email address

 





 


Team A1
TEAM A1
comments@a1-hosting.com
© Copyright 1999 A1-Hosting. All rights reserved